Nikon Eclipse LV100POL Polarizing Microscope
Request a Quote or DemoAdvanced polarized light microscopy under both diascopic and episcopic illumination
Nikon’s Eclipse polarizing microscopes are renowned for their ability to produce brighter, clearer, and higher contrast images. The LV100 POL, available in diascopic and episcopic microscope illumination types, continues this tradition and offers a completely reengineered base for even easier operation. It also features an exclusive high-intensity halogen light source, which delivers brighter images, lower power consumption and less heat generation, thereby reducing the chance of heat-induced focus drift.
Applications:
- Antennae
- Telecom and electronics
- Plastic manufacturing
- Composites
- Fabrics/textiles
- Asbestos
- Telescope optics
- Mobile phones, shavers and watches
Diascopic (Transmitted) Light Source
The high intensity 50W halogen light source incorporates a fly-eye lens design that outputs more light than a 100W lamp. The greater brightness is achieved by optimizing the lamp filament size and optically expanding the size of the light source within the pupil illumination fulfillment.
Lead and Arsenic Free Objective Lenses
The LV100’s CFI LU Plan Fluor EPI P objective series uses eco-glass that is manufactured to the same specifications as Nikon’s proprietary infinity optics (CFI60) system, but without harmful substances such as lead and arsenic.
30mm Focusing Stroke
The focus stroke has been improved to 30mm, facilitating observation of tall samples.
Reverse Type Nosepiece
The reversed-type quadruple nosepiece provides more space at the front of the stage to make handling of specimen slides fast and easy. Another advantage ofCFI60 objectives is that their increased objective lengths and longer working distances provide more working space around the nosepiece to exchange specimens or oil the slide.
Bertrand Lens Incorporated into Design of Intermediate Tube
The Bertrand lens enables both the observation and capture of conoscopic and orthoscopic images. The Bertrand lens is also focusable and centerable.
Rotatable Slider Type Analyzer
The high precision slider-type analyzer located in the intermediate tube is rotatable for a full 360°.
Reduced Focus Drift
Focus drift resulting from light source heat is greatly reduced by virtue of the lower power consumption and heat generated from the new diascopic light source.
Diascopic and Episcopic Polarization
Both Diascopic (transmitted) and Episcopic (reflected) polarization observations are possible by mounting the LV-UEPI universal epi-illuminator.
Episcopic DIC (Differential Interference Contrast)
By mounting the LV-UEPI universal epi-illuminator and optional universal-type nosepiece and DIC accessories including objectives, Episcopic DIC microscopy is possible.
High-Precision Rotating Stage
The stage is large-sized, pre-adjusted and click-stops in 45° increments, making it extremely accurate and easy to rotate. Because the stage is designed to be supported from the bottom of the microscope near the optical axis and incorporates steel cross roller guides, it is twice as stable and durable as conventional stages.
Vibration Resistant Stage
The large sized circular stage is supported near the optical axis and incorporates steal cross roller guides making the stage twice as stable and durable as conventional models. The stage is also extremely accurate, centerable to the optical axis, and provides click-stops at 45° increments.
Main Body - Optical System | CFI60 infinity |
Main Body - Illumination | 12V-50W halogen lamp; 12V-50W DC transformer built-in; Diascopic/Episcopic illumination changeover switch; Fly-eye lens; NCB11, ND8 filters built-in; 12V-100W type optional (requires external power supply) |
Main Body - Focusing | Coaxial coarse/fine focus knob; Focus stroke: 30mm; Coarse: 14mm per rotation; Fine: 0.1mm; Minimum reading: in 1µm increments |
Eyepiece | 10x (F.O.V. 22mm), CM type with crosshair and micrometer scale |
Eyepiece Tube | P-TT Trinocular Tube for polarizing microscopy; P-TB Binocular Tube for polarizing microscopy |
Intermediate Tube | Built-in focusable Bertrand lens removable from optical path; Switchable Conoscopic/Orthoscopic observations; Analyzer built-in; Plate/compensator slot |
Analyzer | 360° rotary dial; Minimum reading angle 0.1° |
Nosepiece | Reversed centering quintuple nosepiece (detachable); DIN slot |
Stage | Top-grade dedicated circular graduated stage. Rotatable 360° horizontally; can be fixed at a specific position. Graduated 360° (in 1° increments); Click stops each 45°. Attachable mechanical stage: 35 x 25mm travel; vernier 0.1mm |
Condenser | Dedicated strain-free swing-out type; P Achromat N.A. 0.9 |
Polarizer | Fixed to the bottom of the condenser holder; Scale |
Objectives | CFI P Achromat 4x, 10x, 20x, 40x, 100x, CFI LU Plan Fluor Epi P 5x, 10x, 20x, 50x,100x |
Episcopic Illuminator | LV-UEPI Universal Epi-illuminator accommodates a 12V-50W illumination transformer. 12V-100W type optional.(requires external power supply) |
Compensators | Standard 1/4 λ & tint plate, quartz wedge or Senarmont compensator can be inserted into intermediate tube slot |
Power Consumption | 1.2A/75W |
Weight | Approx. 17kg (37.4 lbs) (standard trinocular set) |
-
Nikon NIS-Elements Microscope Imaging Software
Provides intuitive tools for image capture, analysis, archiving, and image sharing.
More Information -
Discontinued: Nikon DS-Vi1 Color Microscope Camera
Replaced by: DS-Fi3 HD Color Microscope Camera
-
Discontinued: Nikon DS-Ri2 HD Digital Microscopy Camera
Replaced by: Digital Sight 10
-
Discontinued: Nikon DS-Fi2 Microscope Camera
Replaced by: DS-Fi3 HD Color Microscope Camera